Skip to main content
Tessa NewsLink
Paste a health news link, or browse
Latest checks

Welcome to the Tessa News Link Beta! We are actively improving this experience.

Share Feedback

Source study found

Story checked

Researchers develop more precise way to identify preeclampsia from electronic health records (opens in a new tab)

medicalxpress.com · 2026-11-06

Short answerEvidenceSource

Short answer

Mixed

Mixed.

One claim goes further than the study. One other point was not covered by the paper.

  • 4 supported
  • 1 overstated
  • 1 not covered

Checked against the study summary. The full text wasn't available, so some details couldn't be settled either way.

Notice: Analysis is currently derived from study abstracts. Full-text paper analysis capabilities are currently in development.

Share this check

Help improve NewsLink

Tell us what worked or what needs attention in this check.

Follow the evidence trail
1
2

NewsLink checks it

Mixed

One claim overstates the study. Four of six check out. One claim the study doesn't address.

  • 4 supported
  • 1 overstated
  • 1 not covered
Open claim evidence
3
Then inspect each claim

Evidence layer

Claim by claim

Each claim gets a verdict. Expand it to see the evidence directly below.

6 claims in this story

Showing all 6 claimsChoose a verdict to focus the list.

Then look for missing context

Context layer

What the story left out

Important study details the story did not include.

  • The pragmatic case-finding definitions had high specificity, about 97%, but poor sensitivity, about 29–37%, when compared with the structured-EHR reference definition.

    The story conveys that existing approaches may miss cases, which reflects low sensitivity qualitatively, but it does not report or explain the high specificity finding. Omitting high specificity can make the simpler definitions sound uniformly inaccurate rather than specific but insensitive.

    From retrospective cohort diagnostic-comparison; Retrospective cohort study (linked routine EHR)

  • The diagnostic comparisons are against the study’s structured-EHR reference definition, not an independent clinical gold standard.

    The story uses language such as more precise, more effective, and improved accuracy, but it does not make clear that sensitivity and specificity are measured relative to the authors’ EHR-derived reference definition rather than independent adjudicated diagnoses. This is an interpretation-changing limitation.

    From retrospective cohort diagnostic-comparison; Retrospective cohort study (linked routine EHR)

  • Generalisability is limited because the data came from routine EHRs in two South London NHS trusts over a specific time period, with eligibility requiring at least one recorded blood pressure measurement from 20 weeks and birth at a contributing trust.

    The story identifies the South London cohort but does not present this as a limitation or mention the eligibility restrictions that may exclude pregnancies with incomplete records.

    From Retrospective cohort using linked routinely collected maternity and neonatal EHR; Retrospective cohort study (linked rou

5 things the story did carry across
  • The study was a retrospective observational analysis of linked routine maternity and neonatal EHR data from the eLIXIR-BiSL cohort in two South London NHS trusts, covering Oct 2018 to July 2023 and including 21,120 eligible singleton pregnancies.
  • A broad structured-EHR reference definition aligned with ISSHP/NICE identified higher pre-eclampsia prevalence than semi-structured clinician/drop-down data, ICD-10 codes, or their combination.
  • The paper’s adverse-outcome comparison included severe maternal hypertension and birthweight below the 10th percentile, with lower detection under the simpler case-finding definitions than under the reference definition.
  • Reliance on routine EHR fields means cases or outcomes not recorded in structured or semi-structured fields may be missed, and record inconsistency can affect ascertainment.
  • The paper supports improved case ascertainment and research use of EHR data, but it does not evaluate real-time clinical deployment, interventions, or improved maternal/neonatal outcomes.
Then read the study layer

Study layer

Study at a glance

Scan the study first. Expand only the parts you want to inspect.

Pieces of work

3

Evidence read

study summary

Lead result

secondary data

1Lead resultsecondary dataEvaluate and compare three pragmatic EHR case-finding definitions (semi-structured drop-down data; ICD-10 codes; combined) against the broad structured-EHR reference definition using diagnostic test properties (sensitivity/specificity) and prevalence impact.retrospective cohort diagnostic-comparisonExpand

In plain English

Retrospective cohort diagnostic-comparison study (n=21,120 pregnancies) evaluating three pragmatic EHR case-finding definitions for pre-eclampsia (semi-structured drop-down entries; ICD-10 codes; combined semi-structured+ICD-10) against a broad structured-EHR reference definition aligned with ISSHP and NICE. The study reports prevalence by definition, sensitivity and specificity of each case-finding definition versus the structured reference, and compares detection rates for adverse outcomes (including severe maternal hypertension and birthweight <10th percentile). Case-finding definitions had high specificity (~97%) but low sensitivity (29–37%) and detected substantially fewer adverse outcomes than the structured-EHR reference.

Key findings

  • Pre-eclampsia prevalence varied by ascertainment method, with the structured-EHR reference yielding higher prevalence than pragmatic case-finding approaches.Reference 7.7% (n=1,630); EHR semi-structured 4.5% (n=957); ICD-10 3.7% (n=773); combined 5.8% (n=1,224).
  • Pragmatic case-finding definitions had high specificity but poor sensitivity versus the structured-EHR reference.Specificity ~97% (95% CI 97–97) for all case-finding definitions; sensitivity ranged 29% (26–31) to 37% (35–40).
“...was compared with three case-finding definitions: semi-structured EHR data using drop-down menus (EHR semi-structured definition); ICD-10 codes (ICD-10 definition); and combined semi-structured EHR data and ICD-10 codes (EHR semi-structured and ICD-10 definition). Diagnostic test properties... were assessed.”
2secondary dataOperationalise a broad, guideline-aligned reference definition of pre-eclampsia using structured EHR elements in a linked maternity–neonatal dataset (eLIXIR-BiSL), and estimate pre-eclampsia prevalence under this reference definition.Retrospective cohort using linked routinely collected maternity and neonatal EHRExpand

In plain English

Retrospective cohort study implementing a broad, guideline-aligned reference definition of pre-eclampsia using structured EHR elements in the eLIXIR-BiSL linked maternity–neonatal dataset (two South London NHS trusts, Oct 2018–Jul 2023), and estimating prevalence among eligible singleton pregnancies with ≥1 blood pressure measurement from 20 weeks' gestation. The reference definition (aligned to ISSHP and NICE; incorporated structured evidence of maternal end-organ dysfunction and/or uteroplacental dysfunction) identified 1,630 pre-eclampsia cases (7.7%) among 21,120 included pregnancies.

Key findings

  • Cohort assembly from linked routine maternity and neonatal records yielded 21,120 included singleton pregnancies with required data (from 33,040 pregnancies with antenatal booking information).21,120 included (of 33,040 with booking information)
  • Using the structured-EHR, guideline-aligned reference definition, pre-eclampsia prevalence was 7.7% in the analysed cohort.7.7% (n=1,630 of 21,120)
“We conducted a retrospective cohort study using pseudonymised data from the Early Life Cross Linkage in Research-Born in South London (eLIXIR-BiSL) cohort, linking routine maternity and neonatal records from two trusts in South London, UK, from Oct 1, 2018, to July 11, 2023.”
What this piece can’t prove
  • Use of retrospective routinely collected EHR from two NHS trusts in South London may limit generalisability beyond the study setting/timeframe (Oct 2018–Jul 2023).
  • Analysis required at least one recorded blood pressure measurement from 20 weeks and birth at a contributing trust, which may exclude some pregnancies with incomplete records.
  • Operationalisation relied on structured EHR fields to capture maternal end-organ and uteroplacental dysfunction; cases not recorded in structured fields may be missed.
3secondary dataAssess how choice of pre-eclampsia definition affects detection rates of adverse maternal and neonatal outcomes (eg, severe hypertension, birthweight <10th percentile) in EHR data.Retrospective cohort study (linked routine EHR)Expand

In plain English

In a retrospective cohort of 21,120 singleton pregnancies with ≥1 blood pressure measurement from 20 weeks' gestation in linked maternity and neonatal EHRs (eLIXIR-BiSL; Oct 2018–Jul 2023), the authors compared a broad structured-EHR reference definition of pre-eclampsia with three case-finding definitions (semi-structured EHR, ICD-10 codes, and combined semi-structured+ICD-10) and reported markedly lower detection rates of key adverse outcomes (severe maternal hypertension and birthweight <10th percentile) when using the case-finding definitions versus the reference definition.

Key findings

  • Case-finding definitions captured a smaller proportion of pregnancies with severe maternal hypertension than the structured-EHR reference definition.Severe hypertension detection rates: EHR semi-structured 26.0%; ICD-10 28.1%; combined 32.6%; reference 68.2%.
  • Case-finding definitions captured a smaller proportion of pregnancies with birthweight <10th percentile than the structured-EHR reference definition.Birthweight <10th percentile detection rates: EHR semi-structured 9.7%; ICD-10 10.6%; combined 13.3%; reference 26.2%.
“...Diagnostic test properties and adverse outcome detection rates were assessed.”
What this piece can’t prove
  • Findings derive from routine, pseudonymised EHR data from two NHS trusts in South London and may not generalise to other settings or data systems.
  • Retrospective EHR-based ascertainment and reliance on available structured and semi-structured fields and ICD-10 coding may undercapture some clinical events.

1 further detail could not be confirmed from the summary.

Finally, the search trail

Method layer

NewsLink found the paper. Tessa takes you deeper.

NewsLink checks the story. Tessa is where you inspect the paper, authors, evidence, and research context.

Papers considered

The selected paper, plus nearby candidates.

PubMed, Crossref, Europe PMC · 39 candidate papers

Candidate

Thank you to The Lancet Digital Health statistical and peer reviewers in 2025

The Lancet Digital Health · 2026 · Crossref

And 33 more candidates considered.