Source study found
Story checked
AI used to better predict kidney stone composition (opens in a new tab)
medicalxpress.com · 2026-11-12
Short answer
MixedMixed.
The claims we could check match the study, but some claims were not covered by the evidence reviewed.
- 2 supported
- 1 not covered
Checked against the study summary. The full text wasn't available, so some details couldn't be settled either way.
Notice: Analysis is currently derived from study abstracts. Full-text paper analysis capabilities are currently in development.
Share this check
Help improve NewsLink
Tell us what worked or what needs attention in this check.
The story
AI used to better predict kidney stone composition
medicalxpress.com · 2026-11-12
The story’s checkable claims.
Read the original story (opens in a new tab)NewsLink checks it
Mixed
Every claim we could check holds up. Two of three claims match the study. This overall rating is based only on the claims we could check. One claim the study doesn't address.
- 2 supported
- 1 not covered
The source study
A Validated Artificial Intelligence Model Versus Urinary Supersaturation Alone for Predicting Kidney Stone Composition
Source layer
The 2 papers the story cites
Source study separated from background citations.
The research anchor for the report.
- The study this story reportsmentioned without context
A Validated Artificial Intelligence Model Versus Urinary Supersaturation Alone for Predicting Kidney Stone Composition
Mayo Clinic Proceedings · 2026
- The study this story reportspresented as the new finding
A Validated Artificial Intelligence Model Versus Urinary Supersaturation Alone for Predicting Kidney Stone Composition
Evidence layer
Claim by claim
Each claim gets a verdict. Expand it to see the evidence directly below.
Reading mode
Scan verdicts. Open evidence only when needed.
Browse by verdict
3 claims in this storyShowing all 3 claimsChoose a verdict to focus the list.
Claim 1 of 3Not coveredThe findings, published in Mayo Clinic Proceedings, could provide doctors and other health care professionals with another source of clinical information when a kidney stone is not available for testing, and the model is intended to supplement, not replace, existing test results and trends.View evidenceHide evidence
Why this verdict
The abstract profile supports the underlying development and validation of a predictive model, but it does not verify the clinical-positioning language that the model is intended to be used when a stone is unavailable, or that it should supplement rather than replace existing test results and trends. Those may be full-text discussion or author-commentary points, but they are not established in the supplied abstract-level paper profile.
Study evidence
A supervised AI multiclass model was developed using demographics plus 24-hour urine SS panel variables to predict kidney stone composition categories in a retrospective cohort of 13,000 patients with paired measurements within 90 days.
“Patients with both a 24-hour urine SS panel and a kidney stone composition analysis conducted within 90 days of each other between September 24, 2015, and March 15, 2024, were identified (n=13,000 unique patients).”
Study evidence
On a temporally held-out validation set (Mar 16, 2024–Mar 15, 2025; n=1653), the AI model classifying kidney stone composition achieved higher overall accuracy than EQUIL2-calculated urinary supersaturation alone.accuracy 0.73 vs 0.33
“This model was subsequently validated on a held-out data set of paired measurements collected between March 16, 2024, and March 15, 2025 (n=1653).”
Claim 2 of 3SupportedMayo Clinic researchers developed and tested an artificial intelligence model that used results from a standard 24-hour urine test to predict kidney stone composition more accurately than a conventional urine-based calculation.View evidenceHide evidence
Why this verdict
The abstract profile supports that researchers developed an AI model using demographic characteristics plus 24-hour urine supersaturation panel results and validated it on a held-out temporal dataset. It also supports that the AI model was more accurate than EQUIL2 urinary supersaturation alone. The story simplifies the inputs as a standard 24-hour urine test and the comparator as a conventional urine-based calculation, but the core claim of development, testing/validation, and higher predictive accuracy is supported at abstract depth.
Study evidence
A supervised AI multiclass model was developed using demographics plus 24-hour urine SS panel variables to predict kidney stone composition categories in a retrospective cohort of 13,000 patients with paired measurements within 90 days.
“Patients with both a 24-hour urine SS panel and a kidney stone composition analysis conducted within 90 days of each other between September 24, 2015, and March 15, 2024, were identified (n=13,000 unique patients).”
Study evidence
On a temporally held-out validation set (Mar 16, 2024–Mar 15, 2025; n=1653), the AI model classifying kidney stone composition achieved higher overall accuracy than EQUIL2-calculated urinary supersaturation alone.accuracy 0.73 vs 0.33
“This model was subsequently validated on a held-out data set of paired measurements collected between March 16, 2024, and March 15, 2025 (n=1653).”
Claim 3 of 3SupportedUsing the AI model, researchers correctly predicted kidney stone composition in 73% of patients, compared with 33% using the conventional calculation alone.View evidenceHide evidence
As stated73% vs 33%
Why this verdict
The abstract reports the validation-set comparison directly: AI model accuracy 0.73 versus 0.33 for urinary supersaturation alone, with P<.01. The stated 73% vs 33% matches the paper profile.
Study evidence
On a temporally held-out validation set (Mar 16, 2024–Mar 15, 2025; n=1653), the AI model classifying kidney stone composition achieved higher overall accuracy than EQUIL2-calculated urinary supersaturation alone.accuracy 0.73 vs 0.33
“This model was subsequently validated on a held-out data set of paired measurements collected between March 16, 2024, and March 15, 2025 (n=1653).”
Context layer
What the story left out
Important study details the story did not include.
The paper’s evidence is retrospective observational prediction-model research using patients who had both a 24-hour urine supersaturation panel and stone composition analysis within 90 days, creating potential selection bias.
The story caveats mention intended supplemental use, but they do not mention the retrospective design, the requirement for paired tests within 90 days, or the resulting selection-bias concern.
From Retrospective development cohort; temporal held-out validation
The abstract does not report key modeling details, calibration, confidence intervals, or per-class sensitivity/specificity/predictive values.
These limitations are material to interpreting a prediction model’s readiness and reliability. The story does not acknowledge them.
From Retrospective development cohort; temporal held-out validation
The abstract reports subgroup superiority by age and sex but does not provide subgroup-specific numeric results.
This paper element is not discussed in the story. The omission is less central than the main accuracy comparison but is still a reported validation finding and limitation at abstract depth.
From temporal held-out validation
4 things the story did carry across
- The paper developed a multivariable AI model to predict kidney stone composition categories using demographics plus 24-hour urine supersaturation panel results.
- The model was validated on a temporally held-out validation cohort of paired urine supersaturation panels and stone composition analyses.
- The comparator was EQUIL2-calculated urinary supersaturation alone, not stone analysis itself or usual clinical judgment broadly.
- The main validation finding was higher overall multiclass accuracy for the AI model than supersaturation alone: 0.73 vs 0.33, P<.01.
Study layer
Study at a glance
Scan the study first. Expand only the parts you want to inspect.
Pieces of work
2
Evidence read
study summary
Lead result
secondary data
1Lead resultsecondary dataExternally/temporally validate the AI model on a held-out dataset and compare its predictive performance against EQUIL2-calculated urinary supersaturation (SS) alone, including subgroup performance by age and sex.temporal held-out validationExpandCollapse
In plain English
Temporal held-out validation of an AI prediction model for kidney stone composition (trained on earlier data) using a held-out cohort (Mar 16, 2024–Mar 15, 2025; n=1653) with paired 24-hour urine supersaturation (SS) panels and stone composition. The AI model used demographic features plus EQUIL2-calculated SS values as inputs to classify stones into majority calcium oxalate (CaOx), majority calcium phosphate (CaP), uric acid, or other, and was compared against using EQUIL2 SS alone (delta Gibbs free energy scale). In the validation set the AI model achieved higher overall accuracy than SS alone (0.73 vs 0.33, P<.01) and reportedly outperformed SS alone in analyses stratified by age and sex.
Key findings
- On a temporally held-out validation set (Mar 16, 2024–Mar 15, 2025; n=1653), the AI model classifying kidney stone composition achieved higher overall accuracy than EQUIL2-calculated urinary supersaturation alone.accuracy 0.73 vs 0.33
- The AI model outperformed EQUIL2-calculated SS alone in analyses stratified by age and sex in the validation data set.
“This model was subsequently validated on a held-out data set of paired measurements collected between March 16, 2024, and March 15, 2025 (n=1653).”
What this piece can’t prove
- Abstract does not report model architecture, training procedures, hyperparameters, or internal validation details beyond the temporal hold-out.
- Abstract does not provide information on external validation beyond the described temporal hold-out, nor details on case-mix, setting, or potential spectrum effects.
2 further details could not be confirmed from the summary.
2secondary dataDevelop a multivariable AI model using demographics plus 24-hour urine supersaturation panel results to predict kidney stone composition categories (CaOx, CaP, uric acid, other).Retrospective development cohortExpandCollapse
In plain English
Retrospective development cohort (n=13,000 unique patients) assembled from clinical records of patients with both a 24-hour urine supersaturation (SS) panel and a kidney stone composition analysis within 90 days (2015-09-24 to 2024-03-15). A supervised multiclass AI model was developed to predict kidney stone composition categories (majority calcium oxalate [CaOx], majority calcium phosphate [CaP], uric acid, other) using demographic characteristics plus variables from the 24-hour urine SS panel. Urine SS for CaOx, hydroxyapatite (CaP), brushite (CaP), and uric acid were calculated using the EQUIL2 algorithm and expressed on the delta Gibbs free energy scale. The abstract states the model was subsequently validated on a held-out data set collected after the development window (validation results reported separately).
Key findings
- A supervised AI multiclass model was developed using demographics plus 24-hour urine SS panel variables to predict kidney stone composition categories in a retrospective cohort of 13,000 patients with paired measurements within 90 days.
“Patients with both a 24-hour urine SS panel and a kidney stone composition analysis conducted within 90 days of each other between September 24, 2015, and March 15, 2024, were identified (n=13,000 unique patients).”
What this piece can’t prove
- Retrospective observational design with potential selection bias (requires both 24-hour urine SS and stone composition within 90 days).
- Abstract omits key modeling details: specific algorithm(s), preprocessing, handling of missing data, class balance, cross-validation or internal validation procedures, and hyperparameter tuning.
- Generalizability unknown from abstract: patient population characteristics, clinical settings, and inclusion/exclusion criteria beyond the 90-day pairing are not described.
- Timing window (measurements within 90 days) could allow discordance between urine chemistry and stone composition if clinical status changed between measurements; abstract does not address this potential limitation.
1 further detail could not be confirmed from the summary.
Method layer
NewsLink found the paper. Tessa takes you deeper.
NewsLink checks the story. Tessa is where you inspect the paper, authors, evidence, and research context.
Open the paper in Tessa
A Validated Artificial Intelligence Model Versus Urinary Supersaturation Alone for Predicting Kidney Stone Composition
Mayo Clinic proceedings · 2026
Why this one
Near certain
NewsLink found the paper. Tessa is where you inspect it deeply.
Papers considered
The selected paper, plus nearby candidates.
PubMed, Crossref, Europe PMC · 23 candidate papers
A Validated Artificial Intelligence Model Versus Urinary Supersaturation Alone for Predicting Kidney Stone Composition
Mayo Clinic Proceedings · 2026 · PubMed, Crossref
Canadian Spine Society: 26th Annual Scientific Conference, March 2-6, 2026, Fairmont Banff Springs,, Banff, Alta., Canada.
2026 · Europe PMC
Cortisone, Mayo Clinic, and the 1950 Nobel Prize in Medicine: The Seminal Role of Mayo Clinic Proceedings
Mayo Clinic Proceedings · 2026 · Crossref
Infectious Diseases and Mayo Clinic Proceedings
Mayo Clinic Proceedings · 2026 · Crossref
Reviewers for Mayo Clinic Proceedings: Digital Health (2026)
Mayo Clinic Proceedings: Digital Health · 2026 · Crossref
General Information
Mayo Clinic Proceedings · 2026 · Crossref
And 17 more candidates considered.